Andrews Water Heaters logo

Built to perform

  • Features and benefits
  • Specifications
  • Literature
  • Energy labelling
Features Benefits
Up to 16 litres per minute Satisfies the most demanding applications
Internal or external models available Flexible siting, especially where space is at a premium
Copper-finned tube heat exchanger Low maintenance, reliable and robust
5:1 fully modulating burner Adjusts the burner to meet the desired water temperature with no standby heat loss
Flexible flueing options Suits most applications
Low NOX Environmental savings and compliant with latest legislation
Factory fitted frost protection Can be installed externally and in areas without heating (external model only)
Natural gas or LPG Available for off mains gas areas
Features
Up to 16 litres per minute
Internal or external models available
Copper-finned tube heat exchanger
5:1 fully modulating burner
Flexible flueing options
Low NOX
Factory fitted frost protection
Natural gas or LPG
Benefits
Satisfies the most demanding applications
Flexible siting, especially where space is at a premium
Low maintenance, reliable and robust
Adjusts the burner to meet the desired water temperature with no standby heat loss
Suits most applications
Environmental savings and compliant with latest legislation
Can be installed externally and in areas without heating (external model only)
Available for off mains gas areas

View product specification

When clicked this will open the product specification in PDF format.

Model

  WHiC56 WHiCX56 LWHiC56 LWHiCX56
Product code
7689819 7689821 768920 7689822
Energy
Heat input (net) kW 54 53.5 54 53.5
Heat output (gross)
kW 56 56 56 56
Gross thermal efficiency (EN89)
% 103 104 101 98
ErP 
NOx emissions (0% 02) mg/kWh 42.4 41.5 42.3 50.3
ErP efficiency rating    A A A A
Noise level dBA 58 63 58 62
Performance
Hot water capacity at 25ºC rise litre/min 32 32 32 32
Hot water capacity at 55ºC rise litre/min 15 15 15 15
Operating pressure (unvented) bar 2 2 2 2
Minimum working pressure at 10.3 bar bar 1 1 1 1
Maximum working pressure bar 10 10 10 10
Electrical
Fuse rating amp 10 10 10 10
Electrical power consumption W 75.9 75.9 75.9 75.9
Electrical requirements V 230 230 230 230
Misc.
Weight empty kg 32 32 32 32
Maximum outlet temperature ºC 80 80 80 80
Height mm 615 615 615 615
Width mm 464 464 464 464
Depth mm 240 240 240 240
Service clearance
Front mm 600 600 600 600
Sides mm 200 150 200 150
Above mm 300 300 300 300
Shipping
Shipping width mm 578 578 578 578
Shipping depth mm 359 359 359 359
Shipping height mm 780 780 780 780
Shipping weight kg 37 37 37 37
Accessories
Unvented system kit
  B234 B234 B235 B235
Unvented system kit - multiple units
  B276 B276 B276 B276
Remote controller kit for single units
  7705368 7705368 7705368 7705368
Remote controller kit that links two units
  7705369 7705369 7705369 7705369
Remote controller kit for 3 to 6 units   7705370 7705370 7705370 7705370

Learn more about the FASTflo by downloading product literature. If you can’t find the literature you are looking for, or you have any questions, please contact your Technical Sales Manager who will be able to help.

The Energy Related Products Directive (ErP) has applied to all domestic and commercial heating and hot water products through Europe since September 2015.

From 26th September 2018 any water heater sold must have an efficiency/NOx output rating of C or above. In line with the new ErP legislation, we have upgraded our product range so they are all ErP compliant before the September deadline.

These products are no longer available to buy - to find the energy labels please visit the discontinued product literature page.

FREE site survey