Andrews Water Heaters logo

Built to perform

Features Benefits
30 and 60kW single burners and twin burners between 90 and 120kW With fewer burners both commissioning and planned maintenance costs are minimised. Offering in-built redundancy and flexibility (90 and 120kW twin burners).
Independent service valves and pressure sensors on each heat exchanger in twin burner versions Full built in redundancy and service flexibility as burners and heat exchangers can be isolated.
Low NOx burners Compliant with and exceeds current legislative requirement.
High efficiency modulating pumps (ErP rated A) Improved operating efficiencies with greater temperature control.
Multi-line graphical display Access to live data, settings and history. Easy to use with full control of the burners and accurate charging of integral tank.
Ready to connect into BMS via Modbus protocol Easy integration into BMS for remote monitoring and control; identifies specific problems and maximises maintenance efficiency.
Full anti-legionella functions with strap-on sensor as standard Control of secondary return circuit temperature and pump operation.
Features
30 and 60kW single burners and twin burners between 90 and 120kW
Independent service valves and pressure sensors on each heat exchanger in twin burner versions
Low NOx burners
High efficiency modulating pumps (ErP rated A)
Multi-line graphical display
Ready to connect into BMS via Modbus protocol
Full anti-legionella functions with strap-on sensor as standard
Benefits
With fewer burners both commissioning and planned maintenance costs are minimised. Offering in-built redundancy and flexibility (90 and 120kW twin burners).
Full built in redundancy and service flexibility as burners and heat exchangers can be isolated.
Compliant with and exceeds current legislative requirement.
Improved operating efficiencies with greater temperature control.
Access to live data, settings and history. Easy to use with full control of the burners and accurate charging of integral tank.
Easy integration into BMS for remote monitoring and control; identifies specific problems and maximises maintenance efficiency.
Control of secondary return circuit temperature and pump operation.

Want to know more about MAXXflo EVO
- Register your interest

Get started with the MAXXflo EVO by arranging an appointment with your Area Sales Manager. Simply fill out the form below to register your interest and we'll direct your enquiry to the right person who will be in touch.

* Please input your First Name
* Please input your Last Name
* Please input your Company
* Please input your Job Title
* Please enter an email address
* This field is required
* Please input your Postcode

* Mandatory field